U600 Series Ultrasonic Flaw Detector |
Standard number | TSG R0004-2009 EN12668-1:2000 |
Product Description | IWIN-U600 | IWIN-610 | IWIN-620 | IWIN-630 |
Working principle | Ultrasonic | Ultrasonic | Ultrasonic | Ultrasonic |
Working frequency | (0.2~20)MHz | (0.5~20)MHz | (0.5~20)MHz | (0.5~20)MHz |
Pulse Width | Square wave width 30~1000ns adjustable, step 0.1ns | Square wave width 30~1000ns adjustable, step 0.1ns | Square wave width 30~1000ns adjustable, step 0.1ns | Square wave width 30~1000ns adjustable, step 0.1ns |
Detection range | 0~14000 (Steel longitudinal wave)mm | 0~14000 (Steel longitudinal wave)mm | 0~14000 (Steel longitudinal wave)mm | 0~14000 (Steel longitudinal wave)mm |
Pulse shift | -45~1000(steel longitudinal wave)mm | -45~1000(steel longitudinal wave)mm | -45~1000(steel longitudinal wave)mm | -45~1000(steel longitudinal wave)mm |
Material sound velocity | 300~15000m/s | 300~15000m/s | 300~15000m/s | 300~15000m/s |
Detection method | Negative wave, positive wave, two-way wave, filter, RF wave | Negative wave, positive wave, two-way wave, filter, RF wave | Negative wave, positive wave, two-way wave, filter, RF wave | Negative wave, positive wave, two-way wave, filter, RF wave |
Gain adjustment | 0~110dB: 0.1/1/2/6 step adjustment | 0~110dB: 0.1/1/2/6 step adjustment | 0~110dB: 0.1/1/2/6 step adjustment | 0~110dB: 0.1/1/2/6 step adjustment |
Thickness measurement function | non | non | Normal mode 0.75-300mm, penetration coating 2-150mm | Normal mode 0.75-300mm, penetration coating 2-150mm |
WIFI/HDMI/digital filtering wave | non | non | non | Mobile phone connection/HD projection/digital filtering |
Sluice gate | Incoming gate, loss gate; single gate reading, double gate reading | Incoming gate, loss gate; single gate reading, double gate reading | Incoming gate, loss gate; single gate reading, double gate reading | Incoming gate, loss gate; single gate reading, double gate reading |
DAC、AVG Function | DAC curve、AVG curve | DAC curve、AVG curve | DAC curve、AVG curve | DAC curve、AVG curve |
Attenuator error | Every 12dB+-1dB | Every 12dB+-1dB | Every 12dB+-1dB | Every 12dB+-1dB |
Vertical linearity error | ≤3% | ≤3% | ≤3% | ≤3% |
Horizontal linearity error | ≤0.5% | ≤0.5% | ≤0.5% | ≤0.5% |
Dynamic Range | ≥30dB | ≥30dB | ≥30dB | ≥30dB |
Sensitivity margin | ≥65dB (2.5Z20N Probe) | ≥65dB (2.5Z20N Probe) | ≥65dB (2.5Z20N Probe) | ≥65dB (2.5Z20N Probe) |
Far zone resolution | ≥26dB | ≥26dB | ≥26dB | ≥26dB |
Electrical noise level | ≤10(1~4MHz)% | ≤10(1~4MHz)% | ≤10(1~4MHz)% | ≤10(1~4MHz)% |
Equivalent input noise | <80x10-9V/√Hz | <80x10-9V/√Hz | <80x10-9V/√Hz | <80x10-9V/√Hz |