Product Model

IWIN-P800

Standard number

ASTM D5882

System Noise Voltage

< 2 mV

Dynamic range

>138dB

Amplifier Band

10Hz~10kHz

A/D Resolution

16 bit A/D

Sampling time interval

2us~32768us

Sampling Length

1024, 2048, 4096

Time indication error

<1%

Channel Number

1

Amplification factor

1~128

Data transmission mode

Wireless Cloud Transport (Options)

Trigger mode

Signal triggering

Sensor Sensitivity

100 mV/g

Sensor frequency band

1-10000Hz

Continuous working hours

> 10 hours

Power Supply

Built-in rechargeable lithium battery (+7.4V)

Display

640*480 Capacitance Screen

Operational mode

Touch

Weight

1.24Kg

Size

220x160x50